Yard-Man 1070-4 Betriebsanweisung

Stöbern Sie online oder laden Sie Betriebsanweisung nach Rasenmäher Yard-Man 1070-4 herunter. Yard-Man 1070-4 User`s guide Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - Product Notes

Sun Microsystems, Inc.www.sun.comSubmit comments about this document at: http://www.sun.com/hwdocs/feedbackSun SPARC®EnterpriseM8000/M9000 ServersProd

Seite 2

x SPARC Enterprise M8000/M9000 Servers Product Notes for XCP 1070 • April 2008Note – Patch 118833-xx is a kernel patch that requires special instructi

Seite 3

Preface xi2. Edit the file /tmp/RegistrationProfile.properties to add your username, password, network proxy (if necessary), and port (if required).No

Seite 4

xii SPARC Enterprise M8000/M9000 Servers Product Notes for XCP 1070 • April 20088. Download and install the patches by typing:9. If any of the patches

Seite 5 - Contents

Preface xiiiSun Welcomes Your CommentsSun is interested in improving its documentation and welcomes your comments andsuggestions. You can submit your

Seite 6

xiv SPARC Enterprise M8000/M9000 Servers Product Notes for XCP 1070 • April 2008

Seite 7 - Software Resources

1Sun SPARC EnterpriseM8000/M9000 ServersProduct NotesThis document includes these sections: “New in XCP 1070” on page 1 “Supported Firmware and Soft

Seite 8 - Latest Solaris Patches

2 SPARC Enterprise M8000/M9000 Servers Product Notes for XCP 1070 • April 2008Supported Firmware and SoftwareVersionsTABLE 1 lists the minimum require

Seite 9 - Preface ix

Sun SPARC Enterprise M8000/M9000 Servers Product Notes 3Solaris Patch InformationCurrently, patches are required only for servers running Solaris 10 1

Seite 10 - # shutdown -i6

4 SPARC Enterprise M8000/M9000 Servers Product Notes for XCP 1070 • April 20088. 125127-01 – Reboot your domain before proceeding.9. 125670-0210. 1251

Seite 11 - Preface xi

Sun SPARC Enterprise M8000/M9000 Servers Product Notes 5General Functionality Issues and LimitationsCaution – For dynamic reconfiguration (DR) and hot

Seite 12 - Accessing Documentation

Copyright 2008 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, U.S.A. and FUJITSU LIMITED, 1-1, Kamikodanaka4-chome, Nakah

Seite 13 - Sun Welcomes Your Comments

6 SPARC Enterprise M8000/M9000 Servers Product Notes for XCP 1070 • April 2008 Do not use the Service Processor (SP) as the Network Time Protocol (NT

Seite 14

Sun SPARC Enterprise M8000/M9000 Servers Product Notes 7TABLE 4 XCP Issues and WorkaroundsID Description Workaround6565422 The Latest communication fi

Seite 15 - Sun SPARC Enterprise

8 SPARC Enterprise M8000/M9000 Servers Product Notes for XCP 1070 • April 2008Solaris OS Issues and WorkaroundsThis section contains information about

Seite 16 - Versions

Sun SPARC Enterprise M8000/M9000 Servers Product Notes 96531036 The error message networkinitialization failed appearsrepeatedly after a boot net inst

Seite 17 - Solaris Patch Information

10 SPARC Enterprise M8000/M9000 Servers Product Notes for XCP 1070 • April 20086589833 The DR addboard command might cause asystem hang if you are add

Seite 18 - Limitations

Sun SPARC Enterprise M8000/M9000 Servers Product Notes 116625734 Systems with large number of processors in asingle domain environment might havesubop

Seite 19

12 SPARC Enterprise M8000/M9000 Servers Product Notes for XCP 1070 • April 2008Solaris Issues Fixed in Solaris 10 5/08TABLE 6 lists issues that have b

Seite 20 - Software and Firmware Issues

Sun SPARC Enterprise M8000/M9000 Servers Product Notes 136545143 When kcage daemon is expanding the kcagearea, if the user stack exists in the expande

Seite 21 - XCP Issues and Workarounds

14 SPARC Enterprise M8000/M9000 Servers Product Notes for XCP 1070 • April 20086559504 Messages of the form nxge: NOTICE:nxge_ipp_eccue_valid_check: r

Seite 22 - Solaris OS

Sun SPARC Enterprise M8000/M9000 Servers Product Notes 15Solaris Issues Fixed in Solaris 10 8/07TABLE 7 lists issues that have been fixed in Solaris 1

Seite 23

Copyright 2008 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, U.S.A. et FUJITSU LIMITED, 1-1, Kamikodanaka4-chome, Nakaha

Seite 24

16 SPARC Enterprise M8000/M9000 Servers Product Notes for XCP 1070 • April 20086510861 When using the PCIe Dual-Port Ultra320 SCSIcontroller card (SG-

Seite 25

Sun SPARC Enterprise M8000/M9000 Servers Product Notes 17Sun Management Center Software Issues andWorkaroundsTABLE 8 lists issues and possible workaro

Seite 26

18 SPARC Enterprise M8000/M9000 Servers Product Notes for XCP 1070 • April 2008Sun SPARC EnterpriseM4000/M5000/M8000/M9000Servers XSCF User’s GuidePag

Seite 27

Sun SPARC Enterprise M8000/M9000 Servers Product Notes 19Upgrading From XCP 1041 or Lower▼ To Prepare to Upgrade1. Delete any routes configured on the

Seite 28

20 SPARC Enterprise M8000/M9000 Servers Product Notes for XCP 1070 • April 2008DNS domain name :sun.comnameserver :100.200.300.400interface

Seite 29 - CR ID 6534471 in TABLE 7

Sun SPARC Enterprise M8000/M9000 Servers Product Notes 212. Configure the ISN network.XCP 1050 or later supports dual XSCF configuration. The Inter-SC

Seite 30

22 SPARC Enterprise M8000/M9000 Servers Product Notes for XCP 1070 • April 20081. Log in to the XSCF#0 using an account with platform administrative p

Seite 31 - Workarounds

Sun SPARC Enterprise M8000/M9000 Servers Product Notes 23Caution – The flashupdate command will update one bank, reset the XSCF, andcommence update of

Seite 32

24 SPARC Enterprise M8000/M9000 Servers Product Notes for XCP 1070 • April 2008d. Wait until XSCF firmware reaches the ready state.This can be confirm

Seite 33 - ▼ To Prepare to Upgrade

Sun SPARC Enterprise M8000/M9000 Servers Product Notes 25Confirm no abnormality is found during the update.20. Confirm that both the current and reser

Seite 35 - TABLE 9, “Software

26 SPARC Enterprise M8000/M9000 Servers Product Notes for XCP 1070 • April 2008e. Confirm that XSCF#1 has entered the active state:f. Confirm that no

Seite 36

Sun SPARC Enterprise M8000/M9000 Servers Product Notes 27Additional Software ProceduresThis section contains instructions for accomplishing some of th

Seite 37

28 SPARC Enterprise M8000/M9000 Servers Product Notes for XCP 1070 • April 2008Identifying Degraded Memory in a System▼ To Identify Degraded Memory in

Seite 38 - XSCF> showstatus

Sun SPARC Enterprise M8000/M9000 Servers Product Notes 29▼ To Use the showdevices Command1. Log in to XSCF and type the following command:The followin

Seite 39

30 SPARC Enterprise M8000/M9000 Servers Product Notes for XCP 1070 • April 2008Identifying Permanent Memory in a Target Board▼ To Identify Permanent M

Seite 40

Sun SPARC Enterprise M8000/M9000 Servers Product Notes 31The entry for column 4 perm mem MB indicates the presence of permanent memoryif the value is

Seite 41

32 SPARC Enterprise M8000/M9000 Servers Product Notes for XCP 1070 • April 2008

Seite 42

vContentsPreface viiSun SPARC Enterprise M8000/M9000 ServersProduct Notes 1New in XCP 1070 1Supported Firmware and Software Versions 2Using a WAN Boot

Seite 43

vi SPARC Enterprise M8000/M9000 Servers Product Notes for XCP 1070 • April 2008Sun Management Center Software Issues and Workarounds 17Software Docume

Seite 44

viiPrefaceThese product notes contain important and late-breaking information about the SunSPARC®Enterprise M8000/M9000 servers hardware, software, an

Seite 45

viii SPARC Enterprise M8000/M9000 Servers Product Notes for XCP 1070 • April 2008Sun Java Enterprise ServerThe Sun Java Enterprise Server is a compreh

Seite 46

Preface ixThe Sun Connection Update Manager can be used to reinstall the patches ifnecessary or to update the system with the latest set of mandatory

Kommentare zu diesen Handbüchern

Keine Kommentare